Digital Multimeter 4 Digit True RMS


Digital Multimeter 4 Digit True RMS
Stock Number: 35999 TE
 Review Average:  
 Number of Reviews: 1
 View ReviewsReview this item
$19.95


Availibilty: In Stock   Units: 29
Quantity 



SHARE
    
     Email this to a friend     

Detailed Description


View PDF Data Sheet
DATA SHEET


4 Digit 4000 count Pocket Size, True RMS Auto Range multimeter with Backlight & Auto Off (~15min)
10 function, Backlight, .7" height LCD display.
Includes: 30" test leads, 30" Temperature probe, instructions
Fuse Overload protection.
CAT II/600V
SPECIFICATIONS
DC VOLTS: 4.000V/40.00V/400.0V/600V Accuracy: ±0.5%+3 LSD
AC VOLTS: 4.000V/40.00V/400.0V/600V Accuracy: ±1.0%+3 LSD
DC CURRENT: 999.9mA Accuracy: ±1.0%+4 LSD
9.999A Accuracy:: ± 1.0%+4 LSD
AC CURRENT:
999.9mA Accuracy: ±2.0%+3 LSD
9.999A Accuracy: ±2.0%+3 LSD
RESISTANCE: 4.000k ohm Accuracy: ±1.5%+3 LSD
40.00k ohm/400.0k ohm/4.000M ohm Accuracy: ± 1.0%+3 LSD
40.00M ohm Accuracy: ± 1.5%+3 LSD
CAPACITANCE: 4.000nF Accuracy ± 5.0%+20 Counts
40.00nF/400.0nF/4.000µF/40.00µF/400.0µF Accuracy: ± 3.5%+4 LSD
4mF Accuracy: ± 5.0%+5 LSD
FREQUENCY: 4Hz-10MHz Accuracy: ± 1%+2 LSD
TEMPERATURE: -30ºC to 1000ºC (-22ºF to 1832ºF) Accuracy:± 3%+5 LSD
DIODE
CONTINUNITY: <50 ohm Buzzer
NCV: (Non-Contact AC V Near field)
Requires 2 AAA Batteries (Not Included)
L: 4-5/8" W: 2-3/8" T: 1-1/8" WT: .55


California Proposition 65 Warning WARNING: This product can expose you to chemicals including Nickel which is known to the State of California to cause cancer and which is known to the State of California to cause birth defects and/or other reproductive harm. For more information, go to www.P65Warnings.ca.gov



 Product ReviewsClick here to review this item
low voltage limit at 0.8 V.
The meter functions very well otherwise, but it is rather annoying that it will not measure or display voltages (AC or DC) below 0.8 V. If you need to measure such, keep another meter on hand.
- A.B., DC